tc Server UI must limit the number of maximum concurrent connections permitted.


Overview

Finding ID Version Rule ID IA Controls Severity
V-241573 VROM-TC-000005 SV-241573r879511_rule Medium
Description
Resource exhaustion can occur when an unlimited number of concurrent requests are allowed on a website, facilitating a denial-of-service attack. Mitigating this kind of attack will include limiting the number of concurrent HTTP/HTTPS requests. Mitigating this kind of attack will include limiting the number of concurrent HTTP/HTTPS requests. Each incoming request requires a thread for the duration of that request. If more simultaneous requests are received than can be handled by the currently available request processing threads, additional threads will be created up to the value of the “maxThreads” attribute.
STIG Date
VMware vRealize Operations Manager 6.x tc Server Security Technical Implementation Guide 2023-09-12

Details

Check Text ( C-44849r683579_chk )
At the command prompt, execute the following command:

grep maxThreads /usr/lib/vmware-vcops/tomcat-web-app/conf/server.xml

If the value of “maxThreads” is not “300” or is missing, this is a finding.
Fix Text (F-44808r683580_fix)
Navigate to and open /usr/lib/vmware-vcops/tomcat-web-app/conf/server.xml.

Navigate to and locate .

Configure the with the value 'maxThreads= "300"'.

Note: The node should be configured per the below:

minSpareThreads="50"
name="tomcatThreadPool"