UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

tc Server VCO must produce log records containing sufficient information to establish when (date and time) events occurred.


Overview

Finding ID Version Rule ID IA Controls Severity
V-240753 VRAU-TC-000165 SV-240753r674003_rule Medium
Description
After a security incident has occurred, investigators will often review log files to determine when events occurred. Understanding the precise sequence of events is critical for investigation of a suspicious event. As a Tomcat derivative, tc Server can be configured with an AccessLogValve. A Valve element represents a component that can be inserted into the request processing pipeline. The pattern attribute of the AccessLogValve controls which data gets logged. The %t parameter specifies that the system time should be recorded.
STIG Date
VMware vRealize Automation 7.x tc Server Security Technical Implementation Guide 2021-06-23

Details

Check Text ( C-43986r674001_chk )
At the command prompt, execute the following command:

tail /storage/log/vmware/vco/app-server/localhost_access_log.txt

If the time and date of events are not being recorded, this is a finding.
Fix Text (F-43945r674002_fix)
Navigate to and open /etc/vco/app-server/server.xml.

Navigate to and locate .

Configure the node with the below.

Note: The "AccessLogValve" should be configured as follows:
directory="logs"
pattern="%h %l %u %t "%r" %s %b"
prefix="localhost_access_log."
suffix=".txt"/>