UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Horizon Connection Server must disconnect applications after two hours of idle time.


Overview

Finding ID Version Rule ID IA Controls Severity
V-246900 HRZV-7X-000019 SV-246900r768660_rule Medium
Description
Horizon View is intended to provide remote desktops and applications during for more or less continuous use. If an application is open and goes used for more than two hours, that application must be closed to eliminate the risk of that idle application being usurped. For desktops, sessions will not be disconnected after two hours but the credentials stored with Horizon will be invalidated. Subsequent desktop connection attempts will require reauthentication.
STIG Date
VMware Horizon 7.13 Connection Server Security Technical Implementation Guide 2021-07-30

Details

Check Text ( C-50332r768658_chk )
Log in to the Horizon 7 Console. From the left pane, navigate to Settings >> Global Settings. In the right pane, click the "General Settings" tab. Locate the "Disconnect Applications and Discard SSO Credentials for Idle Users" setting.

If the "Disconnect Applications and Discard SSO Credentials for Idle Users" setting is set to "Never", this is a finding.

If the "Disconnect Applications and Discard SSO Credentials for Idle Users" setting is set to greater than "120" minutes (two hours), this is a finding.
Fix Text (F-50286r768659_fix)
Log in to the Horizon 7 Console. From the left pane, navigate to Settings >> Global Settings. In the right pane, click the "General Settings" tab. Click "Edit". Next to "Disconnect Applications and Discard SSO Credentials for Idle Users", select "After" from the dropdown and fill in "120" minutes in the text field. Click "OK".