The vRA PostgreSQL database must be configured to use a syslog facility.


Overview

Finding ID Version Rule ID IA Controls Severity
V-240306 VRAU-PG-000295 SV-240306r668762_rule Medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability, and system operation may be adversely affected. The appropriate support staff include, at a minimum, the ISSO and the DBA/SA. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).
STIG Date
VMW vRealize Automation 7.x PostgreSQL Security Technical Implementation Guide 2023-09-20

Details

Check Text ( C-43539r668760_chk )
At the command prompt, execute the following command:

# grep '^\s*logging_collector\b' /storage/db/pgdata/postgresql.conf

If "logging_collector" is not "on", this is a finding.
Fix Text (F-43498r668761_fix)
At the command prompt, execute the following commands:

# /opt/vmware/vpostgres/current/bin/psql -U postgres -c "ALTER SYSTEM SET logging_collector TO 'on';"