Date Finding Count (6)
2015-01-05 CAT I (High): 0 CAT II (Med): 5 CAT III (Low): 1
STIG Description
The Video Teleconference Security Technical Implementation Guide (STIG) provides technical guidance for video teleconferencing systems and endpoints implemented on DoD networks. The Video Services Policy STIG works with the Video Teleconference STIG requirements for evaluation on each video teleconferencing (VTC) system review, regardless of the VTC product or release level. Comments or proposed revisions to this document should be sent via e-mail to the following address: disa.letterkenny.FSO.mbx.stig-customer-support-mailbox@mail.mil.

Available Profiles



Findings (MAC I - Mission Critical Classified)

Finding ID Severity Title
V-19659 Medium A VVoIP or VTC hardware endpoint possessing a “PC Port” does not tag its communications traffic using 802.1Q VLAN tagging or the PC port is not disabled.
V-19658 Medium A VVoIP or VTC hardware endpoint possessing a “PC Port” is not configured to block access to the endpoint configuration and communications traffic from the attached PC
V-19624 Medium An Auto-answer feature is not properly disabled.
V-21515 Medium Hardware based VVoIP or IP-VTC endpoint contains a web server, the access to which is not restricted OR which is NOT disabled.
V-21514 Medium Hardware based VVoIP or VTC endpoint web browser capabilities that permit the endpoint to browse the internet or intranet are NOT disabled.
V-19660 Low A VVoIP or VTC endpoint that provides a PC data Port is not configured to disable the PC port (or the port is not physically blocked from use) if a PC or other device is not normally attached