Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-234517 | SRG-APP-000375-UEM-000245 | SV-234517r879748_rule | Medium |
Description |
---|
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks. |
STIG | Date |
---|---|
Unified Endpoint Management Server Security Requirements Guide | 2023-02-13 |
Check Text ( C-37702r851582_chk ) |
---|
Verify the UEM server records time stamps for audit records that meet a granularity of one second for a minimum degree of precision. If the UEM server does not record time stamps for audit records that meet a granularity of one second for a minimum degree of precision, this is a finding. |
Fix Text (F-37667r615195_fix) |
---|
Configure the UEM server to be configured to record time stamps for audit records that meet a granularity of one second for a minimum degree of precision. |