The UEM server must fail to a secure state if system initialization fails, shutdown fails, or aborts fail.


Overview

Finding ID Version Rule ID IA Controls Severity
V-234409 SRG-APP-000225-UEM-000136 SV-234409r617355_rule Medium
Description
Failure to a known safe state helps prevent systems from failing to a state that may cause loss of data or unauthorized access to system resources. Applications or systems that fail suddenly and with no incorporated failure state planning may leave the hosting system available but with a reduced security protection capability. Preserving information system state information also facilitates system restart and return to the operational mode of the organization with less disruption of mission-essential processes. In general, application security mechanisms should be designed so that a failure will follow the same execution path as disallowing the operation. For example, security methods, such as isAuthorized(), isAuthenticated(), and validate(), should all return false if there is an exception during processing. If security controls can throw exceptions, they must be very clear about exactly what that condition means. Abort refers to stopping a program or function before it has finished naturally. The term abort refers to both requested and unexpected terminations. Satisfies:FPT_TST_EXT.1.2
STIG Date
Unified Endpoint Management Server Security Requirements Guide 2020-12-14

Details

Check Text ( C-37594r614237_chk )
Verify the UEM server fails to a secure state if system initialization fails, shutdown fails, or aborts fail.

If the UEM server does not fail to a secure state if system initialization fails, shutdown fails, or aborts fail, this is a finding.
Fix Text (F-37559r614238_fix)
Configure the UEM server to fail to a secure state if system initialization fails, shutdown fails, or aborts fail.