UCF STIG Viewer Logo

The UEM server must use host operating system clocks to generate time stamps for audit records.


Overview

Finding ID Version Rule ID IA Controls Severity
V-234340 SRG-APP-000116-UEM-000067 SV-234340r617403_rule Medium
Description
Without an internal clock used as the reference for the time stored on each event to provide a trusted common reference for the time, forensic analysis would be impeded. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. If the internal clock is not used, the system may not be able to provide time stamps for log messages. Additionally, externally generated time stamps may not be accurate. Applications can use the capability of an operating system or purpose-built module for this purpose. Satisfies: OE.TIMESTAMP, FAU_GEN.1.2(1)
STIG Date
Unified Endpoint Management Server Security Requirements Guide 2020-12-14

Details

Check Text ( C-37525r614030_chk )
Verify the UEM server uses host operating system clocks to generate time stamps for audit records.

If the UEM server does not use host operating system clocks to generate time stamps for audit records, this is a finding
Fix Text (F-37490r614031_fix)
Configure the UEM server to use host operating system clocks to generate time stamps for audit records.