UCF STIG Viewer Logo

The UEM server must enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period.


Overview

Finding ID Version Rule ID IA Controls Severity
V-234310 SRG-APP-000065-UEM-000036 SV-234310r617396_rule Medium
Description
By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute forcing, is reduced. Limits are imposed by locking the account. Satisfies:FMT_SMF.1(2)b. Reference:PP-MDM-431028
STIG Date
Unified Endpoint Management Server Security Requirements Guide 2020-12-14

Details

Check Text ( C-37495r617396_chk )
Requirement is Not Applicable when the UEM server is configured to use DoD Central Directory Service for administrator account authentication.

Verify the UEM server enforces the limit of three consecutive invalid logon attempts by a user during a 15-minute time period.

If the UEM server does not enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period, this is a finding.
Fix Text (F-37460r613941_fix)
Configure the UEM server to enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period.