Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-242199 | TIPP-IP-000360 | SV-242199r997623_rule | High |
Description |
---|
Without an alert, security personnel may be unaware of an impending failure of the audit capability, and the ability to perform forensic analysis and detect rate-based and other anomalies will be impeded. The TPS generates an immediate (within seconds) alert which notifies designated personnel of the incident. Sending a message to an unattended log or console does not meet this requirement since that will not be seen immediately. These messages should include a severity level indicator or code as an indicator of the criticality of the incident. Satisfies: SRG-NET-000248-IDPS-00206, SRG-NET-000249-IDPS-00222, SRG-NET-000385-IDPS-00210 |
STIG | Date |
---|---|
Trend Micro TippingPoint IDPS Security Technical Implementation Guide | 2024-06-10 |
Check Text ( C-45474r710138_chk ) |
---|
1. In the Trend Micro SMS, navigate to "Profiles" and "Shared Settings". 2. Under "Action Sets, if "Remote Syslog", are not enabled for both the "Block+Notify" and "Block+Notify+Trace", this is a finding. |
Fix Text (F-45432r710139_fix) |
---|
1. In the Trend Micro SMS, navigate to "Profiles" and "Shared Settings". 2. Under "Action Sets: a. Select "Block+Notify" and edit. b. Select Notifications, and check "Remote Syslog". c. Select "Finish". |