The TPS must generate a log record so an alert can be configured to, at a minimum, the system administrator when malicious code is detected.


Overview

Finding ID Version Rule ID IA Controls Severity
V-242199 TIPP-IP-000360 SV-242199r754438_rule High
Description
Without an alert, security personnel may be unaware of an impending failure of the audit capability, and the ability to perform forensic analysis and detect rate-based and other anomalies will be impeded. The TPS generates an immediate (within seconds) alert which notifies designated personnel of the incident. Sending a message to an unattended log or console does not meet this requirement since that will not be seen immediately. These messages should include a severity level indicator or code as an indicator of the criticality of the incident. Satisfies: SRG-NET-000248-IDPS-00206, SRG-NET-000249-IDPS-00222, SRG-NET-000385-IDPS-00210
STIG Date
Trend Micro TippingPoint IDPS Security Technical Implementation Guide 2022-06-28

Details

Check Text ( C-45474r710138_chk )
1. In the Trend Micro SMS, navigate to "Profiles" and "Shared Settings".
2. Under "Action Sets, if "Remote Syslog", are not enabled for both the "Block+Notify" and "Block+Notify+Trace", this is a finding.
Fix Text (F-45432r710139_fix)
1. In the Trend Micro SMS, navigate to "Profiles" and "Shared Settings".
2. Under "Action Sets:
a. Select "Block+Notify" and edit.
b. Select Notifications, and check "Remote Syslog".
c. Select "Finish".