Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-242184 | TIPP-IP-000180 | SV-242184r710095_rule | Medium |
Description |
---|
Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Off-loading ensures audit information does not get overwritten if the limited audit storage capacity is reached and also protects the audit record in case the system/component being audited is compromised. This also prevents the log records from being lost if the logs stored locally are accidentally or intentionally deleted, altered, or corrupted. |
STIG | Date |
---|---|
Trend Micro TippingPoint IDPS Security Technical Implementation Guide | 2021-06-09 |
Check Text ( C-45459r710093_chk ) |
---|
1. In the Trend Micro SMS interface, go to the "Admin" tab, and select "Server Properties". 2. Select the "syslog" tab. If a syslog server is not configured to send the following audit logs, this is a finding: - Device Audit - Device System - SMS Audit - SMS system |
Fix Text (F-45417r710094_fix) |
---|
1. In the Trend Micro SMS interface, go to the "Admin" tab, and select "Server Properties". 2. Select the "syslog" tab. 3. Click "New". 4. Under syslog server type the hostname or IP address of the syslog server. 5. Click TCP to ensure logging data is queued in the case of disconnection of the syslog server. 6. Type the port used by the centralized logging server (traditionally it is port 514). 7. Under log type, select "Device Audit". 8. Under facility click "Log Audit". 9. Click Event timestamp under "Include Timestamp in Header". 10. Select "Include SMS hostname in header". Repeat this three more times changing the Log Type to include Device System, SMS Audit, and SMS System. |