UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Information Assurance - KVM or A/B Switch not listed on the NIAP U.S. Government Approved Protection Products Compliance List (PCL) for Peripheral Sharing Switches


Overview

Finding ID Version Rule ID IA Controls Severity
V-245781 IA-10.02.01 SV-245781r865846_rule Medium
Description
Failure to use tested and approved switch boxes can result in the loss or compromise of classified information. REFERENCES: NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: SC-3 and SC-4 DISN Connection Process Guide: http://disa.mil/network-services/enterprise-connections/connection-process-guide NIAP Products Compliance List (PCL): https://www.niap-ccevs.org/index.cfm
STIG Date
Traditional Security Checklist 2022-09-22

Details

Check Text ( C-49212r864547_chk )
1. Check all KVM or A/B switches that switch from NIPR to SIPR - or other low side to high side systems being reviewed.

2. Ensure switches are on the most current approved NIAP Approved Products List (APL) are used for switching between high side and low side devices.

3. Check to ensure that any unapproved switch boxes in use have specific approval for use in the SIPRNet Approval to Connect (ATC) or (IATC) from the Classified Connection Approval Office (CCAO).

NOTE: A KVM used for switching between high (SIPRNet) and low (NIPRNet) shared devices must meet one or both of the following basic criteria:
a. Be on the NIAP Approved Products List (APL) (AKA: Validated Products List [VPL]) AND meet any configuration requirements for the sites' IA environment as a minimum requirement to be used on the DODIN.
b. Based on the NIAP/APL approved products list, the devices listed may be used for switching between peripheral devices across high/low (SIPR/NIPR) domains.

TACTICAL ENVIRONMENT: The check is applicable where KVM devices are in use.


Fix Text (F-49167r864548_fix)
1. All KVM or A/B switches that switch from NIPR to SIPR - or other low side to high side systems being reviewed must be on the most current approved NIAP Approved Products List (APL) for use for switching between high side and low side devices.

2. Any unapproved switch boxes in use (switching from NIPR to SIPR) must have specific approval for use and be addressed in the SIPRNet Approval to Connect (ATC) or IATC from the Classified Connection Approval Office (CCAO).

NOTE: A KVM used for switching between high (SIPRNet) and low (NIPRNet) shared devices must meet one or both of the following basic criteria:
a. Be on the NIAP Approved Products List (APL) (AKA: Validated Products List [VPL]) AND meet any configuration requirements for the sites' IA environment as the minimum requirement to be used on the DODIN.
b. Based on the NIAP/APL approved products list, the devices listed may be used for switching between peripheral devices across high/low (SIPR/NIPR) domains.