UCF STIG Viewer Logo

Information Security (INFOSEC) - Secure Room Storage Standards - Balanced Magnetic Switch (BMS) on Perimeter Doors


Overview

Finding ID Version Rule ID IA Controls Severity
V-31275 IS-02.01.08 SV-41542r2_rule PEPF-2 PESS-1 High
Description
Failure to meet standards for ensuring that there is structural integrity of the physical perimeter surrounding a secure room (AKA: collateral classified open storage area) IAW DoD Manual 5200.01, Volume 3 could result in the undetected loss or compromise of classified material. When a physical Intrusion Detection System (IDS) is used as the supplemental protection measure (in lieu of 4-hour random checks) for secure rooms there is a requirement to place a Balanced Magnetic Switch (BMS) alarm contact on the primary ingress/egress door and any secondary/emergency exit doors. This alarm sensor is an essential part of any properly installed IDS and ensures that doors opened by force or that are left open are immediately detected. A BMS (AKA: triple biased alarm contact) is the most difficult door alarm contact to defeat and must be used in lieu of dual biased or simple alarm contacts.
STIG Date
Traditional Security 2013-07-11

Details

Check Text ( C-40017r5_chk )
Where an IDS is used in lieu of 4-hour random checks, for secure rooms or collateral classified open storage areas containing SIPRNet assets, each perimeter door (primary and secondary) shall be protected by a balanced magnetic switch (BMS) that meets the standards of UL 634.

NOTE: Ensure the alarm contact is an actual BMS, which is defined as a "Triple Biased" alarm contact. Introduction of a foreign magnet by an intruder in an attempt to defeat the BMS will result in an alarm being sent.

If used, Simple and Dual Biased contacts are not BMS and will result in a CAT II finding.

No alarm contacts on all doors is a CAT I finding.

TACTICAL ENVIRONMENT: This check is applicable where Secure Rooms are used to protect classified materials or systems in a tactical environment. The only exception will be for urgent (short term) tactical operations or other contingency situations where fixed facilities and equipment are not yet present or incapable of being used.
Fix Text (F-35186r3_fix)
Where an IDS is used in lieu of 4-hour random checks, for secure rooms or collateral classified open storage areas containing SIPRNet assets, each perimeter door (primary and secondary) must be protected by a balanced magnetic switch (BMS) that meets the standards of UL 634.

NOTE: The alarm contact must be an actual BMS, which is defined as a "Triple Biased" alarm contact. Introduction of a foreign magnet by an intruder in an attempt to defeat the BMS will result in an alarm being sent. Simple and Dual Biased contacts are not BMS and will result in a finding.