The Tanium operating system (TanOS) must alert the ISSO and SA (at a minimum) in the event of an audit processing failure.


Overview

Finding ID Version Rule ID IA Controls Severity
V-254842 TANS-OS-000165 SV-254842r870377_rule Medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without this notification, the security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Audit processing failures include software/hardware errors, failures in the audit capturing mechanisms, and audit storage capacity being reached or exceeded. This requirement applies to each audit data storage repository (i.e., distinct information system component where audit records are stored), the centralized audit storage capacity of organizations (i.e., all audit data storage repositories combined), or both.
STIG Date
Tanium 7.x Operating System on TanOS Security Technical Implementation Guide 2022-10-31

Details

Check Text ( C-58455r870377_chk )
1. Access the TanOS interactively.

2. Press "A" for "Appliance Configuration Menu," and then press "Enter".

3. Press 4 for "Syslog Configuration," and then press "Enter".

4. Press "1" for "Check current status," and then press Enter.

If the syslog status page states, "No existing TanOS syslog forwarding configuration found", this is a finding.

If the syslog status page states, "Syslog forwarding configuration" and the SIEM administrator verifies SIEM is receiving the events correctly and generating notifications for audit processing failure events, this is not a finding.
Fix Text (F-58399r866066_fix)
1. Access the TanOS interactively.

2. Press A for "Appliance Configuration Menu," and then press "Enter".

3. Press "4" for "Syslog Configuration," and then press "Enter".

4. Press 5 for "Configure syslog forwarding," and then press "Enter".

5. Enter the destination host (IP address or hostname) provided by the SIEM administrator, and then press "Enter".

6. Enter the destination port number and press "Enter".

7. If TLS is required for this syslog destination, enter "Yes", otherwise enter "No", and then press "Enter".

8. Enter the destination protocol, "udp" or "tcp", and then press "Enter".

9. Work with the SIEM administrator to validate events are being received, and to configure notifications for audit processing failure events.