UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Tanium application must alert the ISSO and SA (at a minimum) in the event of an audit processing failure.


Overview

Finding ID Version Rule ID IA Controls Severity
V-254898 TANS-AP-000260 SV-254898r960912_rule Medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without this notification, the security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Audit processing failures include software/hardware errors, failures in the audit capturing mechanisms, and audit storage capacity being reached or exceeded. This requirement applies to each audit data storage repository (i.e., distinct information system component where audit records are stored), the centralized audit storage capacity of organizations (i.e., all audit data storage repositories combined), or both.
STIG Date
Tanium 7.x Application on TanOS Security Technical Implementation Guide 2024-06-04

Details

Check Text ( C-58511r867592_chk )
1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multi-factor authentication.

2. Click "Modules" on the top navigation banner.

3. Click "Connect".

4. Review the configured Connections under "Connections" section.

Work with the SIEM administrator to determine if an alert is configured when audit data is no longer received as expected.

If there is no alert configured, this is a finding.
Fix Text (F-58455r867593_fix)
1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multi-factor authentication.

2. Click "Modules" on the top navigation banner.

3. Click "Connect".

4. Expand the left menu.

5. Click "Connections".

6. Configure a Connection for the "Tanium Audit Source" source from the Tanium Application to a SIEM tool.

Work with the SIEM administrator to configure an alert when no audit data is received from Tanium based on the defined schedule of connections.