UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Symantec ProxySG must configure the maintenance and health monitoring to send an alarm when a critical condition occurs for a component.


Overview

Finding ID Version Rule ID IA Controls Severity
V-94693 SYMP-NM-000210 SV-104523r1_rule Medium
Description
Predictable failure prevention requires organizational planning to address device failure issues. If components key to maintaining the device's security fail to function, the device could continue operating in an insecure state. If appropriate actions are not taken when a network device failure occurs, a denial of service condition may occur which could result in mission failure since the network would be operating without a critical security monitoring and prevention function. Upon detecting a failure of network device security components, the network device must activate a system alert message or send an alarm. The type of alarm should ensure that an administrator is made aware of the situation within a period specified in the site's SSP based on mission impact. Alarms may be a message send to an events server, SNMP server, email/text, or a monitored console. The following alarms are required for ProxySG devices used in DoD. General * CPU utilization * Memory utilization * Interface(s) utilization Licensing * User license utilization * Base license expiration Status * Disk * Sensor Count Status * Reboot
STIG Date
Symantec ProxySG NDM Security Technical Implementation Guide 2019-12-20

Details

Check Text ( C-93883r1_chk )
Verify the Symantec ProxySG is configured to send system health notifications.

1. Log on to Web Management Console.
2. Click Maintenance >> Health Monitoring, select the "General" tab.
3. Confirm that the Notification methods are correct for each metric (Log, Trap, and/or Email).

If the Symantec ProxySG is not configured to send system health notifications, this is a finding.
Fix Text (F-100811r1_fix)
Configure the Symantec ProxySG to send system health notifications.

1. Log on to the Web Management Console.
2. Click Maintenance >> Health Monitoring, select the "General" tab.
3. Click on each metric, click "Edit" and set the desired thresholds and notification types (Log, Trap, and/or Email).
4. Click "Apply".

Configure the following alarms at a minimum.
General
* CPU utilization
* Memory utilization
* Interface(s) utilization

Licensing
* User license utilization
* Base license expiration

Status
* Disk
* Sensor Count Status
* Reboot