Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-22297 | GEN000253 | SV-26300r1_rule | ECLP-1 | Medium |
Description |
---|
A synchronized system clock is critical for the enforcement of time-based policies and the correlation of logs and audit records with other systems. If an illicit time source is used for synchronization, the integrity of system logs and the security of the system could be compromised. If the configuration files controlling time synchronization are not protected, unauthorized modifications could result in the failure of time synchronization. |
STIG | Date |
---|---|
Solaris 9 X86 Security Technical Implementation Guide | 2013-07-02 |
Check Text ( C-27396r1_chk ) |
---|
Check for an extended ACL on the NTP configuration file. # ls -l /etc/inet/ntp.conf If the permissions contain a "+", the file has an extended ACL and this is a finding. |
Fix Text (F-23452r1_fix) |
---|
Remove the extended ACL on the NTP configuration file. # getfacl /etc/inet/ntp.conf Remove each ACE returned. # setfacl -d [ACE] /etc/inet/ntp.conf |