UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The system must use at least two time sources for clock synchronization.


Overview

Finding ID Version Rule ID IA Controls Severity
V-22291 GEN000242 SV-26303r1_rule ECSC-1 Medium
Description
A synchronized system clock is critical for the enforcement of time-based policies and the correlation of logs and audit records with other systems. For redundancy, two time sources are required so synchronization continues to function if one source fails. If the system is completely isolated (no connections to networks or other systems), time synchronization is not required as no correlation of events or operation of time-dependent protocols between systems will be necessary. If the system is completely isolated, this requirement is not applicable. NOTE: For the Network Time Protocol (NTP), the requirement is two servers, but it is recommended to configure at least four distinct time servers which allow NTP to effectively exclude a time source not consistent with the others. The system's local clock must be excluded from the count of time sources.
STIG Date
SOLARIS 9 SPARC SECURITY TECHNICAL IMPLEMENTATION GUIDE 2015-10-01

Details

Check Text ( C-27400r1_chk )
Check the root crontab for ntpdate entries.
# crontab -l | grep ntpdate
If the ntpdate command is not invoked with at least two external NTP servers listed, this is a finding.

Check the NTP daemon configuration for at least two external servers.
# grep '^server' /etc/inet/ntp.conf | egrep -v '(127.127.1.1|127.127.1.0)'
If less than two servers or external reference clocks (127.127.x.x other than 127.127.1.0 or 127.127.1.1) are listed, this is a finding.
Fix Text (F-23455r1_fix)
If using ntpdate, add additional NTP servers to the cron job running ntpdate.

If using the NTP daemon, add an additional server line to /etc/inet/ntp.conf for each additional NTP server.