The system clock must be synchronized continuously.


Overview

Finding ID Version Rule ID IA Controls Severity
V-22290 GEN000241 SV-26291r2_rule Medium
Description
A synchronized system clock is critical for the enforcement of time-based policies and the correlation of logs and audit records with other systems. Internal system clocks tend to drift and require periodic resynchronization to ensure their accuracy. Software, such as NTPD, can be used to continuously synchronize the system clock with authoritative sources. Alternatively, the system may be synchronized periodically, with a maximum of one day between synchronizations. If the system is completely isolated (no connections to networks or other systems), time synchronization is not required as no correlation of events or operation of time-dependent protocols between systems will be necessary. If the system is completely isolated, this requirement is not applicable.
STIG Date
SOLARIS 10 SPARC SECURITY TECHNICAL IMPLEMENTATION GUIDE 2017-01-27

Details

Check Text ( None )
None
Fix Text (F-23443r3_fix)
Determine the type of zone that you are currently securing.

# zonename

If the command output is not "global", then NTP must be disabled.

# svcadm disable ntp

If the output from "zonename" is "global", then NTP must be enabled.

# svcadm enable ntp