The SDN controller must be configured to encrypt all southbound Application Program Interface (API) management-plane messages using a FIPS-validated cryptographic module.


Overview

Finding ID Version Rule ID IA Controls Severity
V-206733 SRG-NET-000512-SDN-001045 SV-206733r385561_rule High
Description
An SDN controller can manage and configure SDN-enabled devices using protocols such as SNMP and NETCONF. If an SDN-aware router or switch received erroneous configuration information that was altered by a malicious user, interfaces could be disabled, erroneous IP addresses configured, services removed—all resulting a network disruption or even an outage. Hence, it is imperative to secure the management plane by encrypting all southbound API management-plane traffic or deploying an out-of-band network for this traffic to traverse.
STIG Date
SDN Controller Security Requirements Guide 2024-05-28

Details

Check Text ( C-6990r363137_chk )
Determine if the southbound API management-plane traffic traverses an out-of-band path. If not, review the SDN controller configuration to verify that southbound API management-plane traffic is encrypted using a using a FIPS-validated cryptographic module.

If the southbound API management-plane traffic does not traverse an out-of-band path and is not encrypted using a FIPS-validated cryptographic module, this is a finding.

Note: FIPS-validated cryptographic modules are listed on the NIST Cryptographic Module Validation Program's (CMVP) validation list.
Fix Text (F-6990r363138_fix)
Deploy an out-of-band network to provision paths between SDN controller and SDN-enabled devices as well as all hypervisor hosts that compose the SDN infrastructure to provide transport for southbound API management-plane traffic.

An alternative is to configure the SDN controller to encrypt all southbound API management-plane traffic using a FIPS-validated cryptographic module. Implement a cryptographic module which has a validation certification and is listed on the NIST Cryptographic Module Validation Program's (CMVP) validation list.