UCF STIG Viewer Logo

The Samsung Knox for Android container must implement the management setting: Configure minimum password complexity.


Overview

Finding ID Version Rule ID IA Controls Severity
V-61271 KNOX-39-022000 SV-75751r1_rule Medium
Description
Authentication mechanisms other than a Password Authentication Factor often provide convenience to users, but many of these mechanisms have known vulnerabilities. Configuring a minimum password complexity mitigates the risk associated with a weak authentication factor. SFR ID: FMT_SMF_EXT.1.1 #45
STIG Date
Samsung Android OS 5 with Knox 2.0 Security Technical Implementation Guide 2016-02-24

Details

Check Text ( C-62227r1_chk )
This validation procedure is performed on both the MDM Administration Console and the Samsung Knox for Android device.

Check whether the appropriate setting is configured on the MDM Administration Console:
1. Ask the MDM administrator to display the "Minimum Complexity" setting in the "Android Knox Container -> Container Password Restrictions" rule.
2. Verify the value of the setting is Alphanumeric.

On the Samsung Knox for Android device:
1. Open the Knox Container.
2. Select "Knox Settings".
3. Select "Unlock method".
4. Enter current password.
5. Verify PIN and Pattern are grayed out and cannot be selected.

If the configured value of the "Min Complexity" setting is not Alphanumeric, or if the user is able to select PIN or Pattern, this is a finding.

Note: This configuration setting will allow users to implement fingerprint unlock for the container, which is approved for use. However, this approval does not extend to fingerprint unlock for the Samsung device or any other DoD mobile device.
Fix Text (F-67131r1_fix)
Configure the mobile device to enforce a minimum password complexity of alphanumeric.

On the MDM Console, set the "Min Complexity" value to Alphanumeric in the "Android Knox Container -> Container Password Restrictions" rule.