The router must be configured to advertise a hop limit of at least 32 in Router Advertisement messages for IPv6 stateless auto-configuration deployments.


Overview

Finding ID Version Rule ID IA Controls Severity
V-220144 SRG-NET-000512-RTR-000012 SV-220144r604135_rule Low
Description
The Neighbor Discovery protocol allows a hop limit value to be advertised by routers in a Router Advertisement message being used by hosts instead of the standardized default value. If a very small value was configured and advertised to hosts on the LAN segment, communications would fail due to the hop limit reaching zero before the packets sent by a host reached its destination.
STIG Date
Router Security Requirements Guide 2024-05-28

Details

Check Text ( C-21859r539649_chk )
This requirement is not applicable for the DODIN Backbone.

Review the router configuration to determine if the hop limit has been configured for Router Advertisement messages.

If it has been configured and has not been set to at least 32, it is a finding.
Fix Text (F-21851r457760_fix)