Riverbed Optimization System (RiOS) must enforce the limit of three (3) consecutive invalid logon attempts by a user during a 15-minute time period for web-based management access.


Overview

Finding ID Version Rule ID IA Controls Severity
V-62861 RICX-DM-000025 SV-77351r1_rule Medium
Description
By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.
STIG Date
Riverbed SteelHead CX v8 NDM Security Technical Implementation Guide 2019-10-01

Details

Check Text ( C-63655r1_chk )
Verify that RiOS is configured to limit the number of invalid logon attempts during a 15 minute period to 3.

Navigate to the device Management Console
Navigate to Configure >> Security >> Password Policy

Verify that "Login Attempts Before Lockout:" is set to "3"
Verify that "Timeout for User Login After Lockout (seconds)" is set to "900"

If "Login Attempts Before Lockout" is not set to "3" and/or "Timeout for User Login After Lockout (seconds)" is not set to "900", this is a finding.
Fix Text (F-68779r1_fix)
Configure RiOS to limit the number of invalid logon attempts to 3 during a 15 minute period.

Navigate to the device Management Console
Navigate to Configure >> Security >> Password Policy
Set the value of "Login Attempts Before Lockout:" to "3"
Set the value of "Timeout for User Login After Lockout (seconds);" to "900"

Click "Apply" to save the changes
Navigate to the top of the web page and click "Save" to write changes to memory