The Riverbed NetProfiler must be configured to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC).


Overview

Finding ID Version Rule ID IA Controls Severity
V-256086 RINP-DM-000048 SV-256086r961443_rule Medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
STIG Date
Riverbed NetProfiler Security Technical Implementation Guide 2024-06-10

Details

Check Text ( C-59760r882764_chk )
Go to Administration >> General Settings.

Under "Time Configuration", verify the Time Zone is set to "UTC".

If the Time Zone is not "UTC", this is a finding.
Fix Text (F-59703r882765_fix)
Go to Administration >> General Settings.

Under "Time Configuration", configure the Time Zone to "UTC".