The Riverbed NetProfiler must be configured to record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.


Overview

Finding ID Version Rule ID IA Controls Severity
V-256087 RINP-DM-000049 SV-256087r882769_rule Medium
Description
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.
STIG Date
Riverbed NetProfiler Security Technical Implementation Guide 2023-01-11

Details

Check Text ( C-59761r882767_chk )
Go to Administration >> General Settings.

Under "Time Configuration", verify that redundant NTP servers have been configured.

If NTP is not configured, this is a finding.
Fix Text (F-59704r882768_fix)
Go to Administration >> General Settings.

Under "Time Configuration", enable and configure redundant NTP servers.