Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-251426 | RD6X-00-012600 | SV-251426r879559_rule | Medium |
Description |
---|
Redis Enterprise does not generate all the DoD-required audit records. This could lead to incomplete information as follows: - Without an audit trail, unauthorized access to protected data and attempts to elevate or restrict privileges could go undetected. - It would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. - Without the creation of certain audit logs, it would be difficult to identify attempted attacks, and an audit trail would not be available for some forensic investigation for after-the-fact actions. For a complete list of unsupported audit requirements, email "disa.letterkenny.re.mbx.stig-customer-support-mailbox@mail.mil". Once the identity of the requester has been verified and the specifics of missing audit requirements obtained, risk can be assessed and a determination made as to whether it is acceptable. |
STIG | Date |
---|---|
Redis Enterprise 6.x Security Technical Implementation Guide | 2023-12-18 |
Check Text ( C-54859r808341_chk ) |
---|
This requirement is a permanent finding and cannot be fixed. Redis Enterprise does not currently support session or transactional auditing on the database. Redis Enterprise does not generate all the DoD-required audit records; therefore this is a finding. The site must seek AO or ISSO approval for use of Redis Enterprise 6.x with the understanding that not all of the DoD audit requirements are being met. |
Fix Text (F-54814r806432_fix) |
---|
This requirement is a permanent finding and cannot be fixed. This audit requirement must be continuously monitored. It must be marked as an "open" finding to serve as a reminder to the AO and other stakeholders that this is an approved risk and needs to be reviewed periodically. |