OpenShift must use internal system clocks to generate audit record time stamps.


Overview

Finding ID Version Rule ID IA Controls Severity
V-257525 CNTR-OS-000230 SV-257525r960927_rule Medium
Description
Knowing when a sequence of events for an incident occurred is crucial to understand what may have taken place. Without a common clock, the components generating audit events could be out of synchronization and would then present a picture of the event that is warped and corrupted. To give a clear picture, it is important that the container platform and its components use a common internal clock.
STIG Date
Red Hat OpenShift Container Platform 4.12 Security Technical Implementation Guide 2024-06-10

Details

Check Text ( C-61260r921516_chk )
Verify the chronyd service is enabled and active by executing the following:

for node in $(oc get node -oname); do oc debug $node -- chroot /host /bin/bash -c 'echo -n "$HOSTNAME "; systemctl is-enabled chronyd.service; systemctl is-active chronyd.service' 2>/dev/null; done

If the auditd service is not "enabled" and "active", this is a finding.
Fix Text (F-61184r921517_fix)
Apply the machine config to use internal system clocks for audit records by executing the following:

for mcpool in $(oc get mcp -oname | sed "s:.*/::" ); do
echo "apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 80-chronyd-service-enable-$mcpool
labels:
machineconfiguration.openshift.io/role: $mcpool
spec:
config:
ignition:
version: 3.1.0
systemd:
units:
- name: chronyd.service
enabled: true
" | oc apply -f -
done