UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The router must use its loopback or OOB management interface address as the source address when originating syslog traffic.


Overview

Finding ID Version Rule ID IA Controls Severity
V-14673 NET0898 SV-15341r2_rule Low
Description
Using a loopback address as the source address offers a multitude of uses for security, access, management, and scalability of routers. It is easier to construct appropriate ingress filters for router management plane traffic destined to the network management subnet since the source addresses will be from the range used for loopback interfaces instead of a larger range of addresses used for physical interfaces. Log information recorded by authentication and syslog servers will record the router’s loopback address instead of the numerous physical interface addresses. Syslog messages sent to management servers should use the loopback address as the source address.
STIG Date
Perimeter Router Security Technical Implementation Guide Juniper 2016-07-07

Details

Check Text ( C-12807r2_chk )
Review the configuration and verify the loopback interface address is used as the source address when originating syslog traffic. If the device is managed from an OOB management network, the OOB interface must be used instead

Step 1: Verify that a loopback address has been configured with an IP address. The configuration should look similar to the following.

interfaces {
lo0 {
unit 0 {
family inet {
address 10.10.2.1/32;
}
}
}

Note: Only one loopback interface can be configured on Juniper routers; however, multiple addresses can be defined.

Step 2: Verify that syslog is configured to use the loopback address by comparing the source address defined for syslog with the address configured for the loopback interface. You should find a configuration similar to the examples below:

system {
syslog {
host 192.168.1.100 {
any info;
}
source-address 192.168.1.1;
}
}

Note: If source-address is not specified, then the default-address-selection under system hierarchy must be configured. Configuring system default-address-selection will enable the router to use the loopback interface as the source address for most locally generated IP packets. This configuration would appear as follows:

system {
default-address-selection;

}
}
Fix Text (F-14135r4_fix)
Configure the device to use its loopback or OOB management interface address as the source address when originating syslog traffic.