UCF STIG Viewer Logo

The Palo Alto Networks security platform must have alarms enabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-228662 PANW-NM-000097 SV-228662r856008_rule Low
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability, and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).
STIG Date
Palo Alto Networks NDM Security Technical Implementation Guide 2022-09-14

Details

Check Text ( C-30897r513589_chk )
Go to Device >> Log Settings >> Alarms
If the "Enable Alarms" box is not checked, this is a finding.
Fix Text (F-30874r513590_fix)
Go to Device >> Log Settings >> Alarms
Select the "Edit" icon (the gear symbol in the upper-right corner of the pane).
In the "Alarm Settings" window; select the "Enable Alarms" box.
Select "OK".
Commit changes by selecting "Commit" in the upper-right corner of the screen.
Select "OK" when the confirmation dialog appears.