Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-62751 | PANW-NM-000097 | SV-77241r1_rule | Low |
Description |
---|
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability, and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less). |
STIG | Date |
---|---|
Palo Alto Networks NDM Security Technical Implementation Guide | 2019-12-20 |
Check Text ( C-63559r1_chk ) |
---|
Go to Device >> Log Settings >> Alarms If the "Enable Alarms" box is not checked, this is a finding. |
Fix Text (F-68671r1_fix) |
---|
Go to Device >> Log Settings >> Alarms Select the "Edit" icon (the gear symbol in the upper-right corner of the pane). In the "Alarm Settings" window; select the "Enable Alarms" box. Select "OK". Commit changes by selecting "Commit" in the upper-right corner of the screen. Select "OK" when the confirmation dialog appears. |