Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-62749 | PANW-NM-000096 | SV-77239r1_rule | Low |
Description |
---|
If security personnel are not notified immediately upon storage volume utilization reaching 75%, they are unable to plan for storage capacity expansion. This could lead to the loss of audit information. Note that while the network device must generate the alert, notification may be done by a management server. |
STIG | Date |
---|---|
Palo Alto Networks NDM Security Technical Implementation Guide | 2017-07-07 |
Check Text ( C-63557r1_chk ) |
---|
Go to Device >> Log Settings >> Alarms If the Traffic Log DB, Threat Log DB, Configuration Log DB, System Log DB, Alarm DB, and HIP Match Log DB fields are not "75", this is a finding. |
Fix Text (F-68669r1_fix) |
---|
Go to Device >> Log Settings >> Alarms Select the "Edit" icon (the gear symbol in the upper-right corner of the pane). In the "Alarm Settings" window: Select the "Enable Alarms" box. In the "Traffic Log DB" field, enter "75". In the "Threat Log DB" field, enter "75". In the "Configuration Log DB" field, enter "75". In the "System Log DB" field, enter "75". In the "Alarm DB" field, enter "75". In the "HIP Match Log DB" field, enter "75". Select "OK". Commit changes by selecting "Commit" in the upper-right corner of the screen. Select "OK" when the confirmation dialog appears. |