UCF STIG Viewer Logo

Oracle WebLogic must automatically lock accounts when the maximum number of unsuccessful login attempts is exceeded for an organization-defined time period or until the account is unlocked by an administrator.


Overview

Finding ID Version Rule ID IA Controls Severity
V-235938 WBLC-01-000034 SV-235938r628592_rule Medium
Description
Anytime an authentication method is exposed so as to allow for the utilization of an application interface, there is a risk that attempts will be made to obtain unauthorized access. By locking the account when the pre-defined number of failed login attempts has been exceeded, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced. Specifying a time period in which the account is to remain locked serves to obstruct the operation of automated password guessing tools while allowing a valid user to reinitiate login attempts after the expiration of the time period without administrative assistance.
STIG Date
Oracle WebLogic Server 12c Security Technical Implementation Guide 2021-03-18

Details

Check Text ( C-39157r628590_chk )
1. Access AC
2. From 'Domain Structure', select 'Security Realms'
3. Select realm to configure (default is 'myrealm')
4. Select 'Configuration' tab -> 'User Lockout' tab
5. Ensure the following field values are set:
'Lockout Threshold' = 3
'Lockout Duration' = 15
'Lockout Reset Duration' = 15

If 'Lockout Threshold' is not set to 3 or 'Lockout Duration' is not set to 15 or 'Lockout Reset Duration' is not set to 15, this is a finding.
Fix Text (F-39120r628591_fix)
1. Access AC
2. From 'Domain Structure', select 'Security Realms'
3. Select realm to configure (default is 'myrealm')
4. Select 'Configuration' tab -> 'User Lockout' tab
5. Utilize 'Change Center' to create a new change session
6. Set the following values in the fields as shown:
'Lockout Threshold' = 3
'Lockout Duration' = 15
'Lockout Reset Duration' = 15
7. Click 'Save', and from 'Change Center' click 'Activate Changes' to enable configuration changes