Oracle WebLogic must synchronize with internal information system clocks which, in turn, are synchronized on an organization-defined frequency with an organization-defined authoritative time source.


Overview

Finding ID Version Rule ID IA Controls Severity
V-56259 WBLC-02-000094 SV-70513r1_rule Low
Description
Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronization of system clocks is needed in order to correctly correlate the timing of events that occur across multiple systems. To meet that requirement the organization will define an authoritative time source and frequency to which each system will synchronize its internal clock. Application servers must defer accurate timekeeping services to the operating system upon which the application server is installed.
STIG Date
Oracle WebLogic Server 12c Security Technical Implementation Guide 2016-02-03

Details

Check Text ( C-56811r3_chk )
1. Access EM
2. Select the domain from the navigation tree, and use the dropdown to select 'WebLogic Domain' -> 'Security' -> 'Security Provider Configuration'
3. Beneath 'Audit Service' section, click 'Configure' button
4. Ensure the 'Timezone Settings' radio button is set to 'UTC' so audit logs will be time stamped in Coordinated Universal Time regardless of the time zone of the underlying physical or virtual machine
5. The time stamp will be recorded according to the operating system's set time

If the 'Timezone Settings' radio button is not set to 'UTC', this is a finding.
Fix Text (F-61139r3_fix)
1. Access EM
2. Select the domain from the navigation tree, and use the dropdown to select 'WebLogic Domain' -> 'Security' -> 'Security Provider Configuration'
3. Beneath 'Audit Service' section, click 'Configure' button
4. Set the 'Timezone Settings' radio button to 'UTC' so audit logs will be time stamped in Coordinated Universal Time regardless of the time zone of the underlying physical or virtual machine
5. The time stamp will be recorded according to the operating system's set time
6. Click 'Apply' and restart the servers in the WebLogic domain