The listen-address element defined within the config.xml of the OHS Standalone domain that supports OHS must be configured for secure communication.


Overview

Finding ID Version Rule ID IA Controls Severity
V-64613 OH12-1X-000187 SV-79103r1_rule Medium
Description
Oracle Node Manager is the utility that is used to perform common operational tasks for OHS. When starting an OHS instance, the WebLogic Scripting Tool reads the parameters within the config.xml file to setup the communication to the Node Manager. If the IP address to be used for communication is not specified, the WebLogic Scripting tool will not be able to setup a secure connection to Node Manager.
STIG Date
Oracle HTTP Server 12.1.3 Security Technical Implementation Guide 2019-12-12

Details

Check Text ( C-65355r1_chk )
1. Open $DOMAIN_HOME/config/config.xml with an editor.

2. Search for the "" element within the "" element.

3. If the element does not exist or is not set to the CN of the Node Manager certificate, this is a finding.
Fix Text (F-70543r1_fix)
1. Open $DOMAIN_HOME/config/config.xml with an editor.

2. Search for the "" element within the "" element.

3. Set the "" element to the CN of the Node Manager certificate, add the element if it does not exist.