UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Debugging and trace information used to diagnose OHS must be disabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-64491 OH12-1X-000353 SV-78981r1_rule Medium
Description
Information needed by an attacker to begin looking for possible vulnerabilities in a web server includes any information about the web server and plug-ins or modules being used. When debugging or trace information is enabled in a production web server, information about the web server, such as web server type, version, patches installed, plug-ins and modules installed, type of code being used by the hosted application, and any backends being used for data storage may be displayed. Since this information may be placed in logs and general messages during normal operation of the web server, an attacker does not need to cause an error condition to gain this information.
STIG Date
Oracle HTTP Server 12.1.3 Security Technical Implementation Guide 2018-04-05

Details

Check Text ( C-65243r1_chk )
1. Open $DOMAIN_HOME/config/fmwconfig/components/OHS//httpd.conf and every .conf file (e.g., ssl.conf) included in it with an editor.

2. Search for the "TraceEnable" directive at the OHS server and virtual host configuration scopes.

3. If the directive not set to "Off", this is a finding.
Fix Text (F-70421r1_fix)
1. Open $DOMAIN_HOME/config/fmwconfig/components/OHS//httpd.conf and every .conf file (e.g., ssl.conf) included in it with an editor.

2. Search for the "TraceEnable" directive at the OHS server and virtual host configuration scopes.

3. Set the "TraceEnable" directive to a value of "Off", add the directive if it does not exist.