UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The device is not configured to prevent non-printer administrators from altering the global configuration of the device.


Overview

Finding ID Version Rule ID IA Controls Severity
V-6806 MFD08.002 SV-7031r1_rule High
Description
If unauthorized users can alter the global configuration of the MFD they can remove all security. This can lead to the compromise of sensitive data or the compromise of the network the MFD is attached to.
STIG Date
Multifunction Device and Network Printers STIG 2019-01-04

Details

Check Text ( C-3021r1_chk )
The reviewer will, with the assistance of the SA, verify that the device is configured to prevent non-printer administrators from altering the global configuration of the device.
Fix Text (F-6480r1_fix)
Configured the device to prevent non-printer administrators from altering the global configuration of the device. If the device cannot be configured in this manner, replace the device with one that can be configured in an acceptable manner.