UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Windows Defender AV must be configured to only send safe samples for MAPS telemetry.


Overview

Finding ID Version Rule ID IA Controls Severity
V-75207 WNDF-AV-000011 SV-89887r3_rule Medium
Description
This policy setting configures behavior of samples submission when opt-in for MAPS telemetry is set. Possible options are: (0x0) Always prompt (0x1) Send safe samples automatically (0x2) Never send (0x3) Send all samples automatically.
STIG Date
MS Windows Defender Antivirus Security Technical Implementation Guide 2019-12-12

Details

Check Text ( C-74999r3_chk )
This is applicable to unclassified systems, for other systems this is NA.

Verify the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Windows Defender Antivirus -> MAPS -> "Send file samples when further analysis is required" is set to "Enabled" and "Send safe samples" selected from the drop down box.

Procedure: Use the Windows Registry Editor to navigate to the following key:
HKLM\Software\Policies\Microsoft\Windows Defender\Spynet

Criteria: If the value "SubmitSamplesConsent" is REG_DWORD = 1, this is not a finding.
Fix Text (F-81859r4_fix)
This is applicable to unclassified systems, for other systems this is NA.

Set the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Windows Defender Antivirus -> MAPS -> "Send file samples when further analysis is required" to "Enabled" and select "Send safe samples" from the drop down box.