UCF STIG Viewer Logo

The Exchange Receive connector timeout must be limited.


Overview

Finding ID Version Rule ID IA Controls Severity
V-70049 EX13-MB-000275 SV-84671r1_rule Low
Description
Email system availability depends in part on best practice strategies for setting tuning. This configuration controls the number of idle minutes before the connection is dropped. It works in conjunction with the Maximum Inbound Connections Count setting. Connections, once established, may incur delays in message transfer. If the timeout period is too long, there is risk that idle connections may be maintained for unnecessarily long time periods, preventing new connections from being established.
STIG Date
MS Exchange 2013 Mailbox Server Security Technical Implementation Guide 2019-12-23

Details

Check Text ( C-70523r1_chk )
Review the Email Domain Security Plan (EDSP).

Determine the Connection Timeout value.

Open the Exchange Management Shell and enter the following command:

Get-ReceiveConnector | Select Name, Identity, ConnectionTimeout

For each Receive connector, if the value of ConnectionTimeout is not set to 00:10:00, this is a finding.

or

If ConnectionTimeout is set to other than 00:10:00 and has signoff and risk acceptance in the EDSP, this is not a finding.
Fix Text (F-76285r1_fix)
Update the EDSP.

Open the Exchange Management Shell and enter the following command:

Set-ReceiveConnector -Identity <'IdentityName'> -ConnectionTimeout 00:10:00

Note: The value must be in quotes.

or

The value as identified by the EDSP that has obtained a signoff with risk acceptance.