Exchange Message size restrictions must be controlled on Send connectors.


Overview

Finding ID Version Rule ID IA Controls Severity
V-70021 EX13-MB-000205 SV-84643r1_rule Low
Description
Email system availability depends in part on best practice strategies for setting tuning configurations. For message size restrictions, multiple places exist to set or override inbound or outbound message size. Failure to control the configuration strategy can result in loss of data or system availability. This setting enables the administrator to control the maximum message size on a Send connector. Using connectors to control size limits may necessitate applying message size limitations in multiple places, with the potential of introducing conflicts and impediments in the mail flow. Changing this setting at the connector overrides the global one. Therefore, if operational needs require it, the connector value may be set lower than the global value with the rationale documented in the Email Domain Security Plan (EDSP).
STIG Date
MS Exchange 2013 Mailbox Server Security Technical Implementation Guide 2016-07-19

Details

Check Text ( C-70495r1_chk )
Review the Email Domain Security Plan (EDSP).

Determine the maximum message send size.

Open the Exchange Management Shell and enter the following command:

Get-SendConnector | Select Name, Identity, MaxMessageSize

For each Send connector, if the value of MaxMessageSize is not the same as the global value, this is a finding.

or

If MaxMessageSize is set to a numeric value different from the maximum message send size value documented in the EDSP, this is a finding.
Fix Text (F-76257r1_fix)
Update the EDSP.

Open the Exchange Management Shell and enter the following command:

Set-SendConnector -Identity <'IdentityName'> -MaxMessageSize

Note: The value must be in quotes.

or

The value as identified by the EDSP that has obtained a signoff with risk acceptance.

Repeat the procedures for each Send connector.