Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-70015 | EX13-MB-000190 | SV-84637r1_rule | Low |
Description |
---|
Email system availability depends in part on best practice strategies for setting tuning configurations. This setting controls the maximum number of hops (email servers traversed) a message may take as it travels to its destination. Part of the original Internet protocol implementation, the hop count limit prevents a message being passed in a routing loop indefinitely. Messages exceeding the maximum hop count are discarded undelivered. Recent studies indicate that virtually all messages can be delivered in fewer than 60 hops. If the hop count is set too low, messages may expire before they reach their destinations. If set too high, an undeliverable message may cycle between servers, raising the risk of network congestion. |
STIG | Date |
---|---|
MS Exchange 2013 Mailbox Server Security Technical Implementation Guide | 2016-07-19 |
Check Text ( C-70489r1_chk ) |
---|
Review the Email Domain Security Plan (EDSP). Determine the value for Receive connectors. Open the Exchange Management Shell and enter the following command: Get-ReceiveConnector | Select Name, MaxHopCount For each Receive connector, if the value of MaxHopCount is not set to 60, this is a finding. or If the value of MaxHopCount is set to a value other than 60 and has signoff and risk acceptance in the EDSP, this is not a finding. |
Fix Text (F-76251r1_fix) |
---|
Update the EDSP. Open the Exchange Management Shell and enter the following command: Set-ReceiveConnector -MaxHopCount 60 or The value as identified by the EDSP that has obtained a signoff with risk acceptance. Repeat the procedure for each Receive connector. |