UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Exchange Send connectors must be clearly named.


Overview

Finding ID Version Rule ID IA Controls Severity
V-69833 EX13-EG-000130 SV-84455r1_rule Low
Description
For Send connectors, unclear naming as to direction and purpose increases risk that messages may not flow as intended, troubleshooting efforts may be impaired, or incorrect assumptions may be made about the completeness of the configuration. Collectively, connectors should account for all connections required for the overall email topology design. Simple Mail Transfer Protocol (SMTP) connectors, when listed, must name purpose and direction clearly, and their counterparts on servers to which they connect should be recognizable as their partners.
STIG Date
MS Exchange 2013 Edge Transport Server Security Technical Implementation Guide 2019-03-11

Details

Check Text ( C-70303r1_chk )
Open the Exchange Management Shell and enter the following command:

Get-SendConnector | Select Name, Identity

Review the naming for connectors.

For each Send connector, if the connectors are not clearly named for purpose and direction, this is a finding.
Fix Text (F-76063r1_fix)
Update the EDSP.

Open the Exchange Management Shell and enter the following command:

Set-SendConnector -Name <'NewName'> -Identity <'IdentityName'>

Note: Both the and values must be in quotes.

Repeat the procedure for each Send connector.