UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The MDM server must set the maximum number of invalid password attempts that can be entered to unlock the security container before the MDM server wipes the security container.


Overview

Finding ID Version Rule ID IA Controls Severity
V-24992 WIR-WMS-GD-009-06 SV-30825r2_rule ECWN-1 IAIA-1 Medium
Description
A hacker with unlimited attempts can determine the password of a security container within a few minutes using password hacking tools, which could lead to unauthorized access to the security container and exposure of sensitive DoD data.
STIG Date
Mobile Device Management (MDM) Server Security Technical Implementation Guide (STIG) 2013-01-17

Details

Check Text ( C-31245r8_chk )
This check is not applicable if CAC authentication is used for the security container.

1. Make a list of all iOS security policies listed on the MDM server that have been assigned to iOS devices and review each policy.
2. Select each security policy iOS devices are assigned to and, in turn, verify the required settings are in the policy. Verify the number of allowed invalid attempts is 10 or less (required action will be initiated after 10 or less invalid attempts).

Mark as a finding if number of allowed invalid attempts is not set as required.

Note: If there is a finding, note the name of the policy in the Findings Details section in VMS/Component Provided Tracking Database.
Fix Text (F-27633r4_fix)
Set the maximum number of invalid password attempts to 10 or less.