UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Internet Explorer Bind to Object functionality must be enabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17174 DTOO111 SV-53557r1_rule ECSC-1 Medium
Description
Internet Explorer performs a number of safety checks before initializing an ActiveX control. It will not initialize a control if the kill bit for the control is set in the registry, or if the security settings for the zone in which the control is located do not allow it to be initialized. This functionality can be controlled separately for instances of Internet Explorer spawned by Office applications (for example, if a user clicks a link in an Office document or selects a menu option that loads a web page). A security risk could occur if potentially dangerous controls are allowed to load.
STIG Date
Microsoft Word 2013 STIG 2014-12-23

Details

Check Text ( C-47709r1_chk )
Verify the policy value for Computer Configuration -> Administrative Templates -> Microsoft Office 2013 (Machine) -> Security Settings -> IE Security "Bind to Object" is set to "Enabled" and a check in the 'winword.exe' check box is selected.

Procedure: Use the Windows Registry Editor to navigate to the following key:

HKLM\Software\Microsoft\Internet Explorer\Main\FeatureControl\FEATURE_SAFE_BINDTOOBJECT

Criteria: If the value winword.exe is REG_DWORD = 1, this is not a finding.
Fix Text (F-46481r1_fix)
Set the policy value for Computer Configuration -> Administrative Templates -> Microsoft Office 2013 (Machine) -> Security Settings -> IE Security "Bind to Object" to "Enabled" and place a check in the 'winword.exe' check box.