UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Windows Server 2022 must be configured to audit System - Security System Extension successes.


Overview

Finding ID Version Rule ID IA Controls Severity
V-254330 WN22-AU-000370 SV-254330r848806_rule Medium
Description
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior. Security System Extension records events related to extension code being loaded by the security subsystem. Satisfies: SRG-OS-000327-GPOS-00127, SRG-OS-000458-GPOS-00203, SRG-OS-000463-GPOS-00207, SRG-OS-000468-GPOS-00212
STIG Date
Microsoft Windows Server 2022 Security Technical Implementation Guide 2023-05-03

Details

Check Text ( C-57815r848804_chk )
Security Option "Audit: Force audit policy subcategory settings (Windows Vista or later) to override audit policy category settings" must be set to "Enabled" (WN22-SO-000050) for the detailed auditing subcategories to be effective.

Use the "AuditPol" tool to review the current Audit Policy configuration:

Open "PowerShell" or a "Command Prompt" with elevated privileges ("Run as administrator").

Enter "AuditPol /get /category:*"

Compare the "AuditPol" settings with the following:

If the system does not audit the following, this is a finding.

System >> Security System Extension - Success
Fix Text (F-57766r848805_fix)
Configure the policy value for Computer Configuration >> Windows Settings >> Security Settings >> Advanced Audit Policy Configuration >> System Audit Policies >> System >> Audit Security System Extension with "Success" selected.