Windows Server 2016 must be configured to audit Detailed Tracking - Plug and Play Events successes.


Overview

Finding ID Version Rule ID IA Controls Severity
V-224887 WN16-AU-000160 SV-224887r569186_rule Medium
Description
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior. Plug and Play activity records events related to the successful connection of external devices.
STIG Date
Microsoft Windows Server 2016 Security Technical Implementation Guide 2023-08-22

Details

Check Text ( C-26578r465563_chk )
Security Option "Audit: Force audit policy subcategory settings (Windows Vista or later) to override audit policy category settings" must be set to "Enabled" (WN16-SO-000050) for the detailed auditing subcategories to be effective.

Use the AuditPol tool to review the current Audit Policy configuration:

Open an elevated "Command Prompt" (run as administrator).

Enter "AuditPol /get /category:*"

Compare the AuditPol settings with the following.

If the system does not audit the following, this is a finding.

Detailed Tracking >> Plug and Play Events - Success
Fix Text (F-26566r465564_fix)
Configure the policy value for Computer Configuration >> Windows Settings >> Advanced Audit Policy Configuration >> System Audit Policies >> Detailed Tracking >> "Audit PNP Activity" with "Success" selected.