The Ctrl+Alt+Del security attention sequence for logons must be enabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-225463 WN12-SO-000019 SV-225463r569185_rule Medium
Description
Disabling the Ctrl+Alt+Del security attention sequence can compromise system security. Because only Windows responds to the Ctrl+Alt+Del security sequence, a user can be assured that any passwords entered following that sequence are sent only to Windows. If the sequence requirement is eliminated, malicious programs can request and receive a user's Windows password. Disabling this sequence also suppresses a custom logon banner.
STIG Date
Microsoft Windows Server 2012/2012 R2 Member Server Security Technical Implementation Guide 2021-10-18

Details

Check Text ( C-27162r471731_chk )
If the following registry value does not exist or is not configured as specified, this is a finding:

Registry Hive: HKEY_LOCAL_MACHINE
Registry Path: \Software\Microsoft\Windows\CurrentVersion\Policies\System\

Value Name: DisableCAD

Value Type: REG_DWORD
Value: 0
Fix Text (F-27150r471732_fix)
Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> "Interactive Logon: Do not require CTRL+ALT+DEL" to "Disabled".