Untrusted intranet zone access to Project servers must not be allowed.


Overview

Finding ID Version Rule ID IA Controls Severity
V-70727 DTOO346 SV-85351r1_rule Medium
Description
Allows users to access Project Server Web sites and Workspaces that have not been added to their trusted internet zones. If you enable this setting, users can access Project Server and Microsoft SharePoint Foundation sites that are not in their trusted internet zones. If this setting is disabled or not configured, users are required to add the Project Server and Microsoft SharePoint Foundation sites to their trusted internet site zones.
STIG Date
Microsoft Project 2016 Security Technical Implementation Guide 2016-11-02

Details

Check Text ( C-71211r3_chk )
Verify the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" is set to "Disabled".

Procedure: Use the Windows Registry Editor to navigate to the following key:

HKCU\Software\Policies\Microsoft\Office\16.0\ms project\security

Criteria: If the value TrustWSS is REG_DWORD = 0, this is not a finding.
Fix Text (F-77053r1_fix)
Set the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" to "Disabled".