Run once selection for running outdated ActiveX controls must be disabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-223048 DTBI1105-IE11 SV-223048r879587_rule Medium
Description
This feature keeps ActiveX controls up to date and helps make them safer to use in Internet Explorer. Many ActiveX controls are not automatically updated as new versions are released. It is very important to keep ActiveX controls up to date because malicious or compromised webpages can target security flaws in out-of-date ActiveX controls.
STIG Date
Microsoft Internet Explorer 11 Security Technical Implementation Guide 2023-12-01

Details

Check Text ( C-24721r428694_chk )
In the policy value for Computer Configuration >> Administrative Templates >> Windows Components >> Internet Explorer >> Security Features >> Add-on Management, verify "Remove the Run this time button for outdated ActiveX controls in IE" is set to “Enabled”.

Use the Windows Registry Editor to navigate to the following key:

HKLM\Software\Microsoft\Windows\CurrentVersion\Policies\Ext

If the value "RunThisTimeEnabled" is REG_DWORD = 0, this is not a finding.
Fix Text (F-24709r428695_fix)
In the policy value for Computer Configuration >> Administrative Templates >> Windows Components >> Internet Explorer >> Security Features >> Add-on Management, set "Remove the Run this time button for outdated ActiveX controls in IE" to "Enabled".