Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-214492 | IISW-SI-000259 | SV-214492r508659_rule | Medium |
Description |
---|
Windows Process Activation Service (WAS) manages application pool configuration and may flag a worker process as unhealthy and shut it down. The rapid fail protection must be set to a suitable value. A lack of response from the worker process might mean the worker process does not have a thread to respond to the ping request, or that it is hanging for some other reason. The ping interval and ping response time may need adjustment to gain access to timely information about application pool health without triggering false, unhealthy conditions. |
STIG | Date |
---|---|
Microsoft IIS 8.5 Site Security Technical Implementation Guide | 2020-09-25 |
Check Text ( C-15701r310680_chk ) |
---|
Open the IIS 8.5 Manager. Click the “Application Pools”. Perform for each Application Pool. Highlight an Application Pool to review and click "Advanced Settings" in the "Actions" pane. Scroll down to the "Rapid Fail Protection" section and verify the value for "Failure Interval" is set to "5". If the "Failure Interval" is not set to "5" or less, this is a finding. |
Fix Text (F-15699r310681_fix) |
---|
Open the IIS 8.5 Manager. Click the “Application Pools”. Perform for each Application Pool. Highlight an Application Pool to review and click "Advanced Settings" in the "Actions" pane. Scroll down to the "Rapid Fail Protection" section and set the value for "Failure Interval" to "5" or less. Click “OK”. |